<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The effect of the use of sterile transparent film dressing on the catheter dwell time and the development of catheter-related complications in newborns: Randomized clinical trial

dc.contributor.authorIncekar, Mujde Calikusu
dc.contributor.authorYildiz, Suzan
dc.contributor.authorGul, Yagmur
dc.contributor.authorUzunhan, Ozan
dc.date.accessioned2026-10-09T21:47:54Z
dc.date.issued2025
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractObjective: The aim of this study was to evaluate the effect of sterile transparent film dressing and tape dressing used in peripheral intravenous catheter application in newborns on the catheter dwell time and the development of catheter-related complications. Methods: The study was conducted in the neonatal intensive care unit of a hospital as a randomized controlled trial design. This study was conducted with the group that sterile transparent film dressing and the group that tape dressing methods. Data were collected using newborn follow-up forms, the Infiltration Scale and Phlebitis Scale. Results: There was no statistically significant difference between the two groups referring to the signs of extravasation, phlebitis, and occlusion in newborns related to the catheter dwell time and catheter-related complications (p > 0.05). The scores and signs of infiltration were higher in the tape dressing group (p < 0.05). Conclusion: The use of a sterile transparent film dressing reduces tissue infiltration in neonates with peripheral intravenous catheters. It is recommended that health care professionals working in neonatal intensive care units use sterile transparent film dressings to dress peripheral intravenous catheters. (c) 2024 Elsevier Espana, S.L.U. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
dc.identifier.doi10.1016/j.enfcli.2024.08.006
dc.identifier.issn1130-8621
dc.identifier.issn1579-2013
dc.identifier.issue3
dc.identifier.orcid0000-0002-2528-2185
dc.identifier.orcid0000-0002-4472-2406
dc.identifier.scopus2-s2.0-85207150179
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1016/j.enfcli.2024.08.006
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3511
dc.identifier.volume35
dc.identifier.wosWOS:001516349100008
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynak.digerEmerging Sources Citation Index (ESCI)
dc.language.isoes
dc.publisherElsevier Espana Slu
dc.relation.ispartofEnfermeria Clinica
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260922
dc.subjectNeonatal Nursing
dc.subjectCatheterization Peripheral
dc.subjectInfant Premature
dc.subjectVascular Access Devices
dc.subjectClinical Trial
dc.titleThe effect of the use of sterile transparent film dressing on the catheter dwell time and the development of catheter-related complications in newborns: Randomized clinical trial
dc.title.alternativeEfecto del uso de apósitos estériles de película transparente sobre el tiempo de permanencia del catéter y la aparición de complicaciones relacionadas con el catéter en recién nacidos: ensayo clínico aleatorizado
dc.typeArticle

Files