<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Comparison of stress shielding between endobutton and screw fixation in the latarjet procedure using three-dimensional finite element analysis

dc.contributor.authorUnsal, Seyyid Serif
dc.contributor.authorYildirim, Tugrul
dc.contributor.authorTecirli, Ali
dc.date.accessioned2026-10-09T21:50:51Z
dc.date.issued2026
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractBackgroundThe Latarjet procedure is a well-established surgical technique for the treatment of recurrent anterior shoulder instability. Endobutton fixation systems have recently emerged as an alternative to conventional screw fixation, with the potential advantage of providing a more homogeneous stress distribution across the graft. The purpose of this study was to compare the distribution of Von Mises stress (VMS) in coracoid grafts fixed with screws versus endobuttons using three-dimensional finite element (FE) analysis.MethodsThree-dimensional FE models of the glenoid and coracoid graft were constructed using computed tomography data. Two fixation scenarios were evaluated: [1] Group A - fixation with two cortical screws, and [2] Group B - fixation with an Endobutton system. Identical graft dimensions, positions, and loading conditions were applied. A 50-N anteriorly directed force was applied at the graft-glenoid interface. Material properties were defined as homogeneous, isotropic, and linearly elastic. VMS values were calculated using Abaqus software.ResultsScrew fixation produced localized stress concentrations around the screw holes with limited proximal load transfer, resulting in a heterogeneous graft stress pattern. In contrast, the Endobutton construct demonstrated a more uniform stress distribution across the graft. Although the screw group exhibited a higher mean von Mises stress (16.7 MPa [0.8-23.1]) compared with the Endobutton group (12.3 MPa [5.4-20.9]), a substantially greater proportion of graft volume exceeded the predefined high-stress threshold (>= 15 MPa), indicating localized stress concentration. The Endobutton model showed fewer high-stress regions and improved stress homogeneity.ConclusionEndobutton fixation in the Latarjet procedure results in a more uniform stress distribution across the coracoid graft than screw fixation, which may reduce the risk of graft osteolysis and enhance osteointegration. These findings warrant further validation with cadaveric and clinical studies.
dc.identifier.doi10.1186/s13018-026-06794-4
dc.identifier.issn1749-799X
dc.identifier.issue1
dc.identifier.orcid0000-0003-3535-4100
dc.identifier.pmid41840619
dc.identifier.scopus2-s2.0-105036284595
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1186/s13018-026-06794-4
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3783
dc.identifier.volume21
dc.identifier.wosWOS:001746959400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED)
dc.language.isoen
dc.publisherBmc
dc.relation.ispartofJournal of Orthopaedic Surgery and Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260922
dc.subjectLatarjet Procedure
dc.subjectEndobutton Fixation
dc.subjectScrew Fixation
dc.subjectFinite Element Analysis
dc.subjectVon Mises Stress
dc.subjectGraft Osteolysis
dc.titleComparison of stress shielding between endobutton and screw fixation in the latarjet procedure using three-dimensional finite element analysis
dc.typeArticle

Files