<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The impact of the relationship between lesion diameter and total core length on the detection rate of clinically significant prostate cancer for PI-RADS 3 lesions

dc.contributor.authorYakut, Emrah
dc.date.accessioned2026-10-09T21:46:48Z
dc.date.issued2024
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractBackground The aim of our study was to determine the effect of total core length (TCL) for prostate imaging reporting and data system (PI-RADS) 3 lesions to facilitate clinically significant prostate cancer (csPCa) detection based on the lesion diameter. Materials and methods A total of 149 patients with at least 1 lesion with a PI-RADS 3 were evaluated retrospectively. The lesions with diameters of < 1 cm were categorized as small lesions and lesions of >= 1 cm were categorized as large lesions. The lengths of biopsy cores from PI-RADS 3 lesions were summed for each lesion separately, and TCL was calculated. The relationship between TCL and csPCa was analyzed separately for the small and large groups with multiple logistic regression analyses. Results A total of 208 lesions were detected by multiparametric magnetic resonance imaging (MpMRI) in 149 males included in the study. The mean TCL was 44.68 mm (26-92) and the mean lesion diameter was 10.73 mm (4-27) in PIRADS 3 lesions. For small diameter lesions (< 1 cm), the odds of finding clinically insignificant prostate cancer (ciPCa) increase by 1.67 times if TCL increases by one unit. Hence, increasing TCL for small lesions only increases the odds of ciPCa detection. For large diameter lesions (>= 1 cm), if TCL increases by one unit, the odds of finding ciPCa increase 1.13 times and the odds of finding csPCa increases1.16 times. Accordingly, large lesions are more likely to have both csPCa and ciPCa as TCL increases. Conclusions Our study showed that for PI-RADS 3 lesions, both more csPCa and more ciPCa were detected as TCL increased. However, in lesions with a size of < 1 cm, only ciPCa was detected more frequently as TCL increased. In conclusion, taking more and longer biopsy cores in PI-RADS 3 lesions below 1 cm does not contribute to the detection of csPCa.
dc.description.sponsorshipYuksek Ihtisas University
dc.description.sponsorshipNo Statement Available
dc.identifier.doi10.1007/s00345-024-04845-1
dc.identifier.issn0724-4983
dc.identifier.issn1433-8726
dc.identifier.issue1
dc.identifier.orcid0000-0001-8635-9185
dc.identifier.pmid38488892
dc.identifier.scopus2-s2.0-85187877238
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1007/s00345-024-04845-1
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3421
dc.identifier.volume42
dc.identifier.wosWOS:001184356300001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED)
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofWorld Journal of Urology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260922
dc.subjectClinically Significant Prostate Cancer
dc.subjectLesion Diameter
dc.subjectMultiparametric Magnetic Resonance Imaging
dc.subjectProstate Fusion Biopsy
dc.subjectTotal Core Length
dc.titleThe impact of the relationship between lesion diameter and total core length on the detection rate of clinically significant prostate cancer for PI-RADS 3 lesions
dc.typeArticle

Files