Test-Retest Reliability of the Closed Kinetic Chain upper Extremity Stability Test in Children Aged 7-10 Years
| dc.contributor.author | Gungorenler, Cemre Yaren | |
| dc.contributor.author | Tarsuslu, Tulay | |
| dc.date.accessioned | 2026-10-09T21:49:13Z | |
| dc.date.issued | 2025 | |
| dc.department | Yüksek İhtisas Üniversitesi | |
| dc.description.abstract | The aim of this study is to investigate the test-retest reliability of the Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) and modified-CKCUEST in children aged 7-10 years and to compare the two test versions within the same group. The study was completed with fifty-three children. Average, normalized, and power scores were obtained from the maximum number of touches in 15 x 3 s in the tests. Tests were repeated seven days apart for test-retest reliability. Intraclass Correlation Coefficient (ICC3,1), Standard Error of Measurement (SEM), Minimum Detectable Change (MDC) were tested total/by gender. Children's opinions about the tests were questioned. The test-retest ICC3,1 values for CKCUEST were 0.96 for average score, 0.95 for normalized score, 0.97 for power score. For the modified-CKCUEST, test-retest reliabilities were 0.94, 0.92, 0.96, respectively. CKCUEST and modified-CKCUEST demonstrated excellent test-retest reliability for children aged 7-10 years. Participants stated that the modified-CKCUEST was more suitable as a test position. | |
| dc.identifier.doi | 10.1080/1091367X.2024.2443860 | |
| dc.identifier.endpage | 255 | |
| dc.identifier.issn | 1091-367X | |
| dc.identifier.issn | 1532-7841 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-85212473450 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 246 | |
| dc.identifier.uri | https://doi.org/10.1080/1091367X.2024.2443860 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12794/3638 | |
| dc.identifier.volume | 29 | |
| dc.identifier.wos | WOS:001380663800001 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak.diger | Science Citation Index Expanded (SCI-EXPANDED); Social Science Citation Index (SSCI) | |
| dc.language.iso | en | |
| dc.publisher | Routledge Journals, Taylor & Francis Ltd | |
| dc.relation.ispartof | Measurement in Physical Education and Exercise Science | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WoS_20260922 | |
| dc.subject | Closed Kinetic Chain | |
| dc.subject | Children | |
| dc.subject | Physical Performance Test | |
| dc.subject | Upper Extremity | |
| dc.title | Test-Retest Reliability of the Closed Kinetic Chain upper Extremity Stability Test in Children Aged 7-10 Years | |
| dc.type | Article |







