<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The Effect of Noise Meters Giving Visual and Auditory Alarms Used on Reducing Noise in Neonatal Intensive Care Unit

dc.contributor.authorBalci, Serap
dc.contributor.authorIncekar, Mujde Calikusu
dc.contributor.authorTastekin, Ayhan
dc.date.accessioned2026-10-09T21:53:00Z
dc.date.issued2021
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractAim: This study was conducted to determine the effect of the use of a noise meter emitting visual and auditory alarms on reducing noise. Materials and Methods: The study was conducted in an experimental design in a hospital in a Neonatal Intensive Care Unit (NICU). In the study, a noise meter emitting visual and auditory alarms and a digital noise meter were placed in a room (group 1); whereas, in the other room, only a digital noise meter was placed (group 2). The noise meter emitting visual and auditory alarms was hung on the most visible wall in the room and thus visual and auditory alarms were provided to the staff members in the room. The digital noise meter was hidden behind a closet in the same area in both rooms. The noise levels of the rooms were measured via the digital noise meter in both rooms in a way that data would come in continuously for two weeks. Results: It was found that the total mean noise level in group 1 was significantly lower than group 2 for the two weeks (p<0.01). It was determined that the noise levels on weekdays and at the weekend were significantly lower in group 1 than group 2 in week 1 (p<0.01); whereas, in week 2 there was no difference between the groups in terms of the noise levels on weekdays and at the weekend (p>0.05). Conclusion: The use of a noise meter emitting visual and auditory alarms might be effective in reducing noise in NICUs.
dc.identifier.doi10.4274/jpr.galenos.2021.97720
dc.identifier.endpage461
dc.identifier.issn2147-9445
dc.identifier.issue4
dc.identifier.orcid0000-0002-4472-2406
dc.identifier.orcid0000-0003-1735-4318
dc.identifier.orcid0000-0001-8915-6690
dc.identifier.scopus2-s2.0-85192557445
dc.identifier.scopusqualityN/A
dc.identifier.startpage456
dc.identifier.trdizinid481896
dc.identifier.urihttps://doi.org/10.4274/jpr.galenos.2021.97720
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/481896
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3976
dc.identifier.volume8
dc.identifier.wosWOS:000718894700015
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynak.digerEmerging Sources Citation Index (ESCI)
dc.language.isoen
dc.publisherGalenos Publ House
dc.relation.ispartofJournal of Pediatric Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20260922
dc.subjectNeonatal Intensive Care
dc.subjectNewborn
dc.subjectNoise
dc.subjectNursing
dc.subjectSound
dc.titleThe Effect of Noise Meters Giving Visual and Auditory Alarms Used on Reducing Noise in Neonatal Intensive Care Unit
dc.typeArticle

Files