RELIABILITY OF MAKE AND BREAK TESTS IN ASSESSING INTRINSIC FOOT MUSCLE STRENGTH USING A HANDHELD DYNAMOMETER IN HEALTHY YOUNG ADULTS
| dc.contributor.author | Yazici, Gokhan | |
| dc.contributor.author | Varol, Fatmagul | |
| dc.contributor.author | Volkan Yazici, Melek | |
| dc.contributor.author | Citaker, Seyit | |
| dc.date.accessioned | 2026-10-09T21:51:43Z | |
| dc.date.issued | 2020 | |
| dc.department | Yüksek İhtisas Üniversitesi | |
| dc.description.abstract | Purpose: The make and break tests are used in isometric muscle measurement via a handheld dynamometer. This study aimed to compare the reliability of intrinsic foot muscle strength assessment with break and make tests in healthy young adults. Methods: Seventy-five healthy adults completed the test-retest protocol with five days between tests. The maximal isometric strength measure of intrinsic foot muscles was measured during make/break tests using a handheld dynamometer. Test-retest reliability was calculated using intra-class correlation coefficients (ICC). Minimal detectable changes were calculated using standard error measurements. Results: According to the analysis, the strength results of the break test were higher in all muscles when compared to the make test (p<0.05). The strength measurements of the intrinsic foot muscles was found to have almost perfect test-retest reliability in the make and break test (ICC=0.938-0.986). Conclusion: Healthy adults showed stable test-retest results on all muscle strength measurements of the intrinsic foot muscles. The make and break test carried out usnig the handheld dynamometer is a reliable method for assessing intrinsic foot muscle strength in healthy adults. Both make and break tests are reliable measurements for the strength of intrinsic foot muscles. | |
| dc.identifier.doi | 10.21653/tjpr.736578 | |
| dc.identifier.endpage | 269 | |
| dc.identifier.issn | 2651-4451 | |
| dc.identifier.issn | 2651-446X | |
| dc.identifier.issue | 3 | |
| dc.identifier.orcid | 0000-0002-4215-6797 | |
| dc.identifier.orcid | 0000-0003-2808-9732 | |
| dc.identifier.orcid | 0000-0002-9270-2290 | |
| dc.identifier.scopus | 2-s2.0-85103218415 | |
| dc.identifier.scopusquality | Q4 | |
| dc.identifier.startpage | 263 | |
| dc.identifier.trdizinid | 415706 | |
| dc.identifier.uri | https://doi.org/10.21653/tjpr.736578 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/415706 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12794/3861 | |
| dc.identifier.volume | 31 | |
| dc.identifier.wos | WOS:000610077700008 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.indekslendigikaynak.diger | Emerging Sources Citation Index (ESCI) | |
| dc.language.iso | en | |
| dc.publisher | Turkey Assoc Physiotherapists | |
| dc.relation.ispartof | Turkish Journal of Physiotherapy Rehabilitation-Turk Fizyoterapi ve Rehabilitasyon Dergisi | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WoS_20260922 | |
| dc.subject | Adult | |
| dc.subject | Foot | |
| dc.subject | Muscle Strength | |
| dc.subject | Reproducibility | |
| dc.title | RELIABILITY OF MAKE AND BREAK TESTS IN ASSESSING INTRINSIC FOOT MUSCLE STRENGTH USING A HANDHELD DYNAMOMETER IN HEALTHY YOUNG ADULTS | |
| dc.title.alternative | Sağlikli genç yetİşkİnlerde dİnamometre İle İntrİnsİk ayak kas kuvvetİ değerlendİrİlmesİnde "make" ve "break" testlerİnİn güvenİrlİğİ | |
| dc.type | Article |







