Hand Size Reduces the Reliability of K-Force® Grip Dynamometer
| dc.contributor.author | Karademir, Feray | |
| dc.contributor.author | Uysal, Ozgun | |
| dc.contributor.author | Tek, Sule Tuzen | |
| dc.contributor.author | Cakiryilmaz, Esra Merve | |
| dc.contributor.author | Firat, Tuzun | |
| dc.date.accessioned | 2026-10-09T21:50:41Z | |
| dc.date.issued | 2026 | |
| dc.department | Yüksek İhtisas Üniversitesi | |
| dc.description.abstract | Background Objective evaluation of grip strength is crucial for determining functional status of patients and demonstrating treatment effectiveness. A novel dynamometer, K-Force (R) Grip, has been developed that can work in conjunction with smart devices. However, the device has a smaller circumference compared to the Jamar (R) Plus+ and lacks an adjustable grip width, unlike the Jamar (R) Plus+. The aim of this study was to assess the validity and reliability of the K-Force (R) Grip across different hand sizes in healthy subjects.Methods We recruited 1 23 healthy subjects (n=246 hands) and categorized them based on hand length and span. Grip strength was measured using both the Jamar (R) Plus + hydraulic hand dynamometer and the K-Force (R) Grip dynamometer.Results Inter-device consistency was excellent for the overall population (ICC=0.937) and for individuals with large hand spans and long hand lengths. It was good for other anthropometric groups. However, ICC estimates for absolute inter-device agreement indicated high variability and were unstable (as indicated by the confidence intervals including zero). BlandAltman plots suggest K-Force (R) values are systematically lower than those from the Jamar (R) Plus+.Conclusion The devices should not be used interchangeably in research settings. For clinical follow-up, the Jamar (R) Plus + dynamometer is recommended, especially in adolescent populations where hand growth continues over time. | |
| dc.identifier.doi | 10.1177/17589983251347238 | |
| dc.identifier.endpage | 28 | |
| dc.identifier.issn | 1758-9983 | |
| dc.identifier.issn | 1758-9991 | |
| dc.identifier.issue | 1 | |
| dc.identifier.orcid | 0000-0003-4096-347X | |
| dc.identifier.orcid | 0000-0002-0697-4290 | |
| dc.identifier.orcid | 0000-0002-3390-6066 | |
| dc.identifier.orcid | 0000-0002-1859-1836 | |
| dc.identifier.scopus | 2-s2.0-105008070629 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 22 | |
| dc.identifier.uri | https://doi.org/10.1177/17589983251347238 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12794/3771 | |
| dc.identifier.volume | 31 | |
| dc.identifier.wos | WOS:001506250000001 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak.diger | Emerging Sources Citation Index (ESCI) | |
| dc.language.iso | en | |
| dc.publisher | Sage Publications Ltd | |
| dc.relation.ispartof | Hand Therapy | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.relation.sdg | Goal-02: Zero Hunger | |
| dc.relation.sdg | Goal-03: Good Health and Well-Being | |
| dc.relation.sdg | Goal-05: Gender Equality | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WoS_20260922 | |
| dc.subject | Grip Strength | |
| dc.subject | Reliability | |
| dc.subject | Muscle Strength Dynamometer | |
| dc.subject | Hand Grip Measurement | |
| dc.subject | Hand Size | |
| dc.title | Hand Size Reduces the Reliability of K-Force® Grip Dynamometer | |
| dc.type | Article |