<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Evaluation of atrial electromechanical properties in patients with masked hypertension

dc.contributor.authorOzkan, Selcuk
dc.contributor.authorYilmaz, Omer Calar
dc.contributor.authorYavuz, Bunyamin
dc.date.accessioned2026-10-09T21:49:10Z
dc.date.issued2020
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractPurpose: In this study, we evaluated the electromechanical properties of atriums in patients with masked hypertension by using tissue Doppler echocardiographic technique to predict the predisposition to atrial arrhythmias. Methods: A total of 118 subjects were included in the study. Twenty-four-hour blood pressure monitorization (ABPM) was used to determinate the masked hypertension in the study group. Tissue Doppler imaging was used to find intra-left and -right atrial electromechanical delay (AEMD) and inter-atrial electromechanical delay. The results compared between patients with masked hypertension and without. Results: There were 55 (%46.6) patients with masked hypertension and 63 (%53.4) patients without masked hypertension without any difference regarding age sex heart rate. No statistically significant difference was found in intra-right AEMD between the groups. Left ventricular end-diastolic and systolic diameters (p <0.01 vs p=0.034), left ventricular posterior and septal wall thickness (p < .01 vs p < .01), left ventricular mass index (p <0.01), left atrium volume (p = 0.02), and indexed left atrial volume (p <0 .01) were high in patients with masked hypertension Inter-AEMD (48.07 +/- 11.49 ms vs 43.73 +/- 8.61 p=0.02) and intra-left AEMD (24.8 +/- 6.35 ms vs 21.42 +/- 7.99 ms p=0.013) were significantly higher in masked hypertensive patients. Conclusions: Masked hypertension shares the same clinical outcomes like overt hypertension. Any effort must be given to prevent unwanted events in masked hypertensive patients. According to our findings we suggesting that masked hypertensive patients must be evaluated for atrial arrhythmia.
dc.identifier.doi10.1080/10641963.2020.1714644
dc.identifier.endpage530
dc.identifier.issn1064-1963
dc.identifier.issn1525-6006
dc.identifier.issue6
dc.identifier.orcid0000-0001-5245-5216
dc.identifier.pmid31933376
dc.identifier.scopus2-s2.0-85078039950
dc.identifier.scopusqualityQ2
dc.identifier.startpage527
dc.identifier.urihttps://doi.org/10.1080/10641963.2020.1714644
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3633
dc.identifier.volume42
dc.identifier.wosWOS:000507024700001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED)
dc.language.isoen
dc.publisherTaylor & Francis Inc
dc.relation.ispartofClinical and Experimental Hypertension
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260922
dc.subjectAtrial Arrhythmias
dc.subjectMasked Hypertension
dc.subjectTissue Doppler Imaging
dc.subjectAtrial Electromechanical Delay
dc.subjectHypertension
dc.titleEvaluation of atrial electromechanical properties in patients with masked hypertension
dc.typeArticle

Files