<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Incidence of medical device-related pressure injuries and identification of risk factors in the neonatal unit

dc.contributor.authorYarkiner, Zalihe
dc.contributor.authorBahar, Arzu
dc.contributor.authorSonmez, Munevver
dc.contributor.authorKapan, Emine
dc.contributor.authorSahin, Simge
dc.contributor.authorKostekci, Ezgi
dc.contributor.authorErdeve, Omer
dc.date.accessioned2026-10-09T21:48:07Z
dc.date.issued2024
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractAim: This study was conducted to investigate the incidence of medical device-related pressure injuries (MDRPIs) and the risk factors influencing their occurrence in the neonatal intensive care unit (NICU). Method: This study is a prospective, descriptive study. The research was conducted with 116 newborns between June 1, 2022, and June 1, 2023. Newborns who stayed in the neonatal intensive care unit for at least 24 h were observed daily for medical device-related pressure injuries under and around each medical device throughout their stay in the intensive care unit. The Case Report Form, MDRPIs Monitoring Form, Braden Q scale for children, National Pressure Injury Advisory Panel (NPIAP) Pressure Grading, and Glasgow Coma Scale were used in the research. Results: The incidence of medical device-related pressure injuries is 35.3 % (41/116). It was found that 38.1 % (16/42) of medical device-related pressure injuries developed due to Near-Infrared Spectroscopy (NIRS) probes, and 33.5 % (14/42) developed due to medical devices related to the respiratory system. In terms of anatomical location, 38.1 % occurred on the forehead, and 23.8 % on the arm/leg. The difference between birth weight, gestational age, development of MDRPIs in newborns receiving sedation and inotropes was found to be statistically significant. Regression analysis identified gestational age (p = 0.040, OR = 0.795, 95%CI = [0.632-1.000]) as an independent risk factor for the occurrence of medical device-related pressure injuries. Conclusions: The incidence of medical device-related pressure injuries in newborns was relatively high in this study, with gestational age being the most significant risk factor for MDRPIs formation. It is crucial for neonatal intensive care nurses to consider associated risk factors while providing newborn care and implement appropriate preventive measures to reduce the incidence of MDRPIs.
dc.identifier.doi10.1016/j.jtv.2024.09.005
dc.identifier.endpage922
dc.identifier.issn0965-206X
dc.identifier.issn1876-4746
dc.identifier.issue4
dc.identifier.orcid0000-0001-7646-1864
dc.identifier.orcid0000-0001-9747-850X
dc.identifier.orcid0000-0002-4766-6454
dc.identifier.pmid39304460
dc.identifier.scopus2-s2.0-85204468427
dc.identifier.scopusqualityQ2
dc.identifier.startpage916
dc.identifier.urihttps://doi.org/10.1016/j.jtv.2024.09.005
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3540
dc.identifier.volume33
dc.identifier.wosWOS:001374448700001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED); Social Science Citation Index (SSCI)
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofJournal of Tissue Viability
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260922
dc.subjectMedical Device-Related Pressure Injuries
dc.subjectNeonatal Intensive Care Unit
dc.subjectNursing
dc.subjectNewborn
dc.titleIncidence of medical device-related pressure injuries and identification of risk factors in the neonatal unit
dc.typeArticle

Files