<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The sensitivity and specificity of the balance evaluation systems test-BESTest in determining risk of fall in stroke patients

dc.contributor.authorSahin, Ilknur Ezgi
dc.contributor.authorGuclu-Gunduz, Arzu
dc.contributor.authorYazici, Gokhan
dc.contributor.authorOzkul, Cagla
dc.contributor.authorVolkan-Yazici, Melek
dc.contributor.authorNazliel, Bijen
dc.contributor.authorTekindal, Mustafa Agah
dc.date.accessioned2026-10-09T21:52:20Z
dc.date.issued2019
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractBACKGROUND: Balance disorders cause disability in stroke and increase risk of falls. The Balance Evaluation Systems Test (BESTest), examines balance, determines parameters causing balance disorders, provides information on risk factors for falls. OBJECTIVE: To investigate the sensitivity and specificity of the BESTest in determining the risk of fall in stroke patients. METHODS: Fifty patients with chronic stroke were included in the study. Balance was assessed using BESTest, Berg Balance Scale (BBS), Activity Specific Balance Confidence scale (ABC) and Biodex-BioSway Balance System. To examine the content validity of BESTest, the relationship between BESTest and other balance assessment methods was examined. The internal consistency reliability of BESTest was evaluated by Cronbach's alpha coefficient. Analysis of receiver operating characteristics (ROC) was performed to determine cut-off point, sensitivity and specificity. RESULTS: BESTest, BBS, ABC and Biodex-BioSway Balance System results of faller stroke patients were worse than that of non-faller (p < 0.05). Internal consistency of BESTest was found to be Cronbach's alpha = 0.960. The BESTest value of area under the curve (AUC) was 0.844, with a cut-off point of 69.44%, a sensitivity of 75% and a specificity of 84.6% (p < 0.01). CONCLUSION: BESTest is reliable and valid with high sensitivity and specificity in determining the risk of fall in stroke patients.
dc.identifier.doi10.3233/NRE-182558
dc.identifier.endpage77
dc.identifier.issn1053-8135
dc.identifier.issn1878-6448
dc.identifier.issue1
dc.identifier.orcid0000-0001-9367-9910
dc.identifier.orcid0000-0002-4060-7048
dc.identifier.orcid0000-0002-4720-9691
dc.identifier.pmid30814369
dc.identifier.scopus2-s2.0-85062240090
dc.identifier.scopusqualityQ2
dc.identifier.startpage67
dc.identifier.urihttps://doi.org/10.3233/NRE-182558
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3900
dc.identifier.volume44
dc.identifier.wosWOS:000459548900007
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED); Social Science Citation Index (SSCI)
dc.language.isoen
dc.publisherSage Publications Inc
dc.relation.ispartofNeurorehabilitation
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.relation.sdgGoal-03: Good Health and Well-Being
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260922
dc.subjectStroke
dc.subjectBalance
dc.subjectBestest
dc.subjectRisk Of Falls
dc.titleThe sensitivity and specificity of the balance evaluation systems test-BESTest in determining risk of fall in stroke patients
dc.typeArticle

Files