<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Comparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation

dc.contributor.authorAksoy, Mustafa
dc.contributor.authorAsena, Leyla
dc.contributor.authorGungor, Sirel Gur
dc.contributor.authorKucukoduk, Ali
dc.contributor.authorAkman, Ahmet
dc.date.accessioned2026-10-09T21:47:06Z
dc.date.issued2021
dc.departmentYüksek İhtisas Üniversitesi
dc.description.abstractPurpose This study aims to compare postoperative refractive error results using Pentacam (Oculus Optikgerate GmbH) Holladay equivalent keratometry readings (EKR) or IOLMaster 700 (Carl Zeiss Meditec AG) keratometry (K) values in IOL power calculation. Material and methods This retrospective study included 54 eyes of 31 patients who underwent cataract surgery. Preoperative biometric measurements of all patients were obtained using IOLMaster 700 followed by Pentacam measurements. IOLMaster 700 K measurements on horizontal (K1) and vertical (K2) axes and EKR measurements on 2 mm (EKR2mm), 3 mm (EKR3mm) and 4.5 mm (EKR4.5 mm) corneal zones were recorded. EKR4.5 mm value and IOLMaster 700 K values were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas to calculate predictive refractive error (PRE). Absolute refractive error (ARE) was calculated as the absolute difference between actual postoperative refractive error (APRE) and PRE values. Results Mean age was 72.2 +/- 8.3 (51-87) years and mean IOL power was 21.5 +/- 2.9 D (18-23 D). There was no significant difference between PRE values when IOLMaster 700 K measurements and EKR4.5 mm K measurements were used in Holladay-II, SRK/T, Haigis, and Hoffer-Q formulas (p = 0.571, p = 0.833, p = 0.165, p = 0.347, respectively). There was no significant difference between APRE and ARE values (p = 0.124). According to mean ARE results, the closest estimate was achieved when the IOLMaster 700 K values were used in the Holladay-II formula (p = 0.271). Conclusion IOLMaster 700 K measurement and Pentacam EKR4.5 mm measurements can be used interchangeably. IOLMaster 700 K values yielded the most predictive measurement of the refractive result using the Holladay-II formula.
dc.description.sponsorshipBaskent University Research Fund
dc.description.sponsorshipThis study was funded by Baskent University Research Fund.
dc.identifier.doi10.1007/s10792-021-01781-6
dc.identifier.endpage2212
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue6
dc.identifier.orcid0000-0003-1513-7686
dc.identifier.orcid0000-0002-6848-203X
dc.identifier.orcid0000-0001-8024-4758
dc.identifier.orcid0000-0001-6178-8362
dc.identifier.pmid33733281
dc.identifier.scopus2-s2.0-85102555775
dc.identifier.scopusqualityQ2
dc.identifier.startpage2205
dc.identifier.urihttps://doi.org/10.1007/s10792-021-01781-6
dc.identifier.urihttps://hdl.handle.net/20.500.12794/3452
dc.identifier.volume41
dc.identifier.wosWOS:000629929800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynak.digerScience Citation Index Expanded (SCI-EXPANDED)
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20260922
dc.subjectOptical Biometry
dc.subjectIolmaster 700
dc.subjectPentacam
dc.subjectCataract Surgery
dc.subjectEquivalent Keratometry Readings
dc.titleComparison of refractive outcomes using Scheimpflug Holladay equivalent keratometry or IOLMaster 700 keratometry for IOL power calculation
dc.typeArticle

Files